Zappi Navigation Menus
Main Menu Options | Description | |||
---|---|---|---|---|
Charge Log | Today | Log of charge sessions | ||
Yesterday | ||||
Week | ||||
Month | ||||
Year | ||||
Total | ||||
Custom Date | ||||
Event Log | Today | Log of events | ||
Yesterday | ||||
Week | ||||
Custom Date | ||||
WCS | ||||
Readings | READINGS 1/9 | Status: Mode: | Current status and charging mode of the unit | |
Exporting: Importing: | Power being exported to or imported from the grid respectively | |||
Charging: | Power level in Watts being supplied to the EV | |||
Pilot (PWM): | Control Pilot PWM | |||
Charge Current: / I (A) | AC current supplied to the EV | |||
Unit Temp: | Internal temperature of the zappi unit | |||
READINGS 2/9 | Voltage: | Supply voltage to the unit | ||
Voltage Max: | Maximum supply voltage since switch-on | |||
Voltage Min: | Minimum supply voltage since switch-on | |||
Frequency: | Grid frequency | |||
Exporting: Importing: | Power being exported to or imported from the grid respectively | |||
PH1 PH2 PH3 | Indicates which phases are active when charging | |||
READINGS 3/9 | Exporting: Importing: | Power being exported to or imported from the grid respectively | ||
Generation: | Power from the generator (if available) | |||
Consumption: | Power consumed by the house (if available) | |||
Diverted: | Total diverted power (inc. all myenergi devices) | |||
Charging: | Power currently being supplied to the EV | |||
Charge Energy: | Energy supplied to EV during current charge session | |||
Time: | Duration of current charge session | |||
READINGS 4/9 | Exporting: Importing: | Power being exported to or imported from the grid respectively | ||
Battery: | If an AC battery is being monitored the battery power reading is shown: Discharging (+) Charging (-) | |||
Britain GMT/BST | The Time Zone that has been set in the zappi | |||
LOC: | Local time | |||
UTC: | Coordinated Universal Time | |||
READINGS 5/9 | CP (Control Pilot) related debug information | |||
READINGS 6/9 | DSR related debug information | |||
READINGS 7/9 | Power Readings | Debug screen in preparation for automatic switching between a single phase and three phase charging | ||
READINGS 8/9 | Packet Counters | Displays activity over the wireless and Ethernet links | ||
READINGS 9/9 | Packet Counters | Display shows the different information packets being sent by the zappi to myenergi hub | ||
Information | INFORMATION 1/4 | Status: | Status of the unit | |
Serial No.: | Serial number of the unit | |||
Firmware: | Firmware version installed in the unit | |||
Assembled: | Factory assembly date | |||
Cal Date: | Calibration changed date | |||
Power Fail: | Time and date of last supply failure | |||
INFORMATION 2/4 | Grid Sensor: | Grid current sensor source | ||
Last Fault: | Last recorded fault code | |||
Fault Date: | Date and time of last recorded fault code | |||
Hub Registration Code: | The registration code used to register on the app. WILL ONLY SHOW IF A HUB IS PAIRED. | |||
zappi 1ph Untethered zappi 1ph Tethered zappi 3ph Untethered zappi 3ph Tethered zappi 3ph ! | Identifies the zappi type e.g. 3 phase or single phase / tethered or untethered An ‘!’ mark shows a missing phase for 3 phase units | |||
INFORMATION 3/4 | Network ID: | Network information for this device when linked to other devices using myenergi radio frequency (RF) network (Only shows if connected to other devices) | ||
Device Address: | ||||
Master Address: | ||||
Channel: | ||||
EUI: | ||||
MNID: | ||||
EV Active: | EV– auto updates on 3 phase zappis following the first charge session. Active– amount of active phases | |||
INFORMATION 4/4 | Time: | Current Time | ||
Date: | Current Date | |||
Up Time: | Length of time passed since last switch on | |||
DDL: II: LGA: MGA: DSR: | Network load control limiting information: – DDL = Dynamic Device Limit (A) – II = Input current (Amps) – LGA = Load Group Limit Active (Y/N) – MGA = Monitor Group Active (Y/N) – DSR = Demand Side Response Active (Watts and time to live) – see Load Balancing / Current Limiting | |||
Linked Devices Info | DEVICES PWR NOW | Power currently being drawn by the linked devices | ||
DEVICES PW ALLOT | Available power allotted to the linked devices | |||
DEVICES PWR MAX | Maximum power that can be used by each device | |||
DEVICES PW MIN | Minimum power that can used by each device – see Linking Devices | |||
DEVICES MISC | Further information about power allocation of linked devices: – Total Allotted = Total power allotted to all devices – Total Loads = Power consumed by all devices – Surplus Power = Unallocated power – O/D Power = Total power over-drawn by devices – Export Timer = Delay before surplus is allocated | |||
Charge Settings | ECO+ Settings | Min Green Level: | ECO+ charge mode settings – see Charging Modes | |
Start/Stop Delay: | ||||
Plug-in Charge | Allows zappi to force a charge session the first time the EV is plugged in. Required by some EV’s if main charge does not start immediately. | |||
Manual Boost | Manual Boost settings – see Manual Boost | |||
Smart Boost | Smart Boost settings – see Smart Boost | |||
Boost Timer | Programmable boost times – see Boost Timer | |||
Default Mode | The mode that the zappi will start in following a power cut or reset. Can be set to “FAST / ECO / ECO+ / MEM” (MEM stands for memory, i.e. last set mode before zappi reset) | |||
ECO/ECO+ | The number of phases zappi will use in ECO and ECO+ modes. Can be set to “1PH” or “3PH” (This option is only available on 3 phase models) | |||
Settings | Time & Date | Time: | Sets the current time | |
Date: | Sets the date in Format (see below) | |||
Format: | Sets the format of the date | |||
Auto DST: | Automatic Daylight Saving Time adjustment | |||
Zone: | Sets the Time Zone | |||
Update from Cloud: | Sets the time automatically providing a hub is connected. If set to “ON” the time and date cannot be adjusted manually.Note: From v3.033 firmware, this setting will automatically be turned on if the zappi is paired with a hub | |||
Display & Sound | Language | Sets the language for the main screen and menus | ||
Icons | Generation: | Generation icon can be sun or wind | ||
Monitoring: | If there is no generation on-site then generation monitoring can be switched off and the icon will not be shown on the main screen. | |||
Backlight | Sets the duration the display backlight remains on after a button press | |||
Contrast | Sets the display contrast | |||
Set Buzzer: | Switches the buzzer ON or OFF for button presses and mode changes | |||
RGB LED | TEST | Test function to customize LED on front cover | ||
Brightness | Sets the brightness of LED | |||
Colours | Customize your own LED colours | |||
Lock Function | EV plugged: | Lock is active only when EV is plugged in | ||
EV unplugged: | Lock is active only when EV is unplugged | |||
Timeout: | Length of time for the lock to reactivate after unlocking | |||
Lock Code: | The lock code can be changed here (Default is 44444) | |||
Auto Hide: | Hide the main screen when zappi is locked | |||
Charge: | Allows charge sessions without unlocking zappi with the pin code | |||
Test: | Test the lock solenoid when NO cable is inserted | |||
Advanced | Advanced menu and settings (passcode protected) Default passcode: 0000 |